Exd Flame Detector Weather Shield

29600-228 The Flame Detector Weather Shield protects the device from inclement conditions. Protects against water ingress Protects sensor from direct sunlight
29650-070 Additional Head for the Auto-Aligning Beam Detector.

55000-268APO The XP95 Reflective Beam Detector differs from a traditional beam detector in that it is a single unit which houses a transmitter, a receiver and the control electronics. Loop-powered Compatible with Discovery and XP95 protocols Incorporates a short-circuit isolator Automatic drift compensation Automatic reset following alarm or fault condition
Reflective Beam Detector Head (Add-on) – Auto-Aligning

29650-070 Additional Head for the Auto-Aligning Beam Detector.
Intelligent Reflective Beam Detector – Auto-Aligning

SA7100-100APO The Intelligent Auto-Aligning Beam Detectors use the light obscuration principle and sees light produced by the transmitter. Beam detectors are ideal to monitor large open areas and buildings with high ceilings. EN 54-12 & EN 54-18 Certified Allows use of 2 detector heads per low level controller Each detector head configurable from 8m to […]
Beam Detector Surface Mounting Plate

29600-528 Surface Mounting Plate for Auto-Aligning Beam Detector.
Beam Detector Prism Plate (4 prisms)

29600-529 Mounting Plate (4 Prisms).
Beam Detector Prism Plate (1 prism)

29600-530 Mounting Plate (1 Prism) for the Auto-Aligning Beam Detectors.
Beam Detector Extension Kit (50-100m)

29600-526 Extension Kit for the Auto-Aligning Beam Detector.
Beam Detector Bracket

29600-527 Universal Bracket for the Auto-Aligning Beam Detector.
Beam Detector Backbox

29600-241 The Beam Detector Backbox allows easy first fixing of the cabling and terminations to the XP95 Reflective Beam Detector. The backbox can be surface or flush mounted. Aesthetically pleasing
XP95 DIN-Rail Zone Monitor Module – Isolating

55000-812APO The XP95 DIN-Rail Zone Monitor Module is used to power and control a zone of up to 20 Apollo Series 65, Orbis or equivalent fire detectors and report their status to the fire control panel. EN 54-17 & EN 54-18 Certified Allows conventional detection zones to be easily added to addressable systems Allows DIN-Rail […]
XP95 DIN-Rail Mini Switch Monitor Module – Isolating

55000-760APO The XP95 DIN-Rail Mini Switch Monitor Module is used to monitor one or more single pole, volt free contacts connected on a single pair of cables and report status to fire control panel. EN 54-17 & EN 54-18 Certified Designed for use where space is limited Allows DIN-Rail mounting Priority and non-priority settings Pre-alarm’ […]
XP95 DIN-Rail Isolator – Dual Channel

55000-802APO The XP95 DIN-Rail Isolator – Dual Channel provides two independent isolators which sense and isolate short circuits on Discovery and XP95 loops and spurs. Loop-powered Polarity sensitive Up to 20 detectors can be installed between isolators Allows fully isolated spurs
XP95 DIN-Rail Input/Output Module (250V AC)

55000-797APO The XP95 DIN-Rail Input/Output Module is used to monitor single pole, volt free contact inputs and control mains switching relay output contacts. EN 54-17 & EN 54-18 Certified Allows DIN-Rail mounting XP95, Discovery compatible
XP95 DIN-Rail AV Control Module (5 Amperes)

55000-182APO The XP95 DIN-Rail AV Control Module is used to control and monitor the operation of a circuit of conventional sounders or bells. EN 54-18 Certified Allows sounders to be operated 1 second on, 1 second off May be synchronised with loop sounders Allows DIN-Rail mounting XP95, Discovery compatible