Intelligent Input/Output Module (Twin)

SA4700-104APO The Intelligent Input/Output Module provides the function of two Input/Output Modules to monitor single pole, volt free contact inputs and control relay output contacts. EN 54-17 & EN 54-18 Certified Meets BS 7273-4 failsafe requirements Ergonomic design for ease of wiring and faster installation Suitable for semi flush or surface mounting XP95, Discovery and […]
ntelligent Input/Output Module (250V AC)

SA4700-103APO The Intelligent Input/Output Module is used to monitor two single pole, volt free contact inputs and control mains switching relay output contacts. EN 54-17 & EN 54-18 Certified Two input channels Meets BS 7273-4 failsafe requirements Ergonomic design for ease of wiring and faster installation Suitable for semi flush or surface mounting XP95, Discovery […]
Intelligent Input/Output Module

SA4700-102APO The Intelligent Input/Output Module is used to monitor single pole, volt free contact inputs and control relay output contacts. EN 54-17 & EN 54-18 Certified Meets BS 7273-4 failsafe requirements Ergonomic design for ease of wiring and faster installation Suitable for semi flush or surface mounting XP95, Discovery and CoreProtocol compatible
XP95 Manual Call Point – Isolating

55100-908APO The XP95 Manual Call Point is used to manually initiate an alarm signal on the fire detection system. EN 54-11 & EN 54-17 Certified Reports an alarm in under 0.2 seconds ‘Plug and Play’ terminal connections for faster wiring Continuity link for wiring test before commissioning Suitable for semi flush or surface mounting XP95 […]
XP95 Manual Call Point

55100-905APO The XP95 Manual Call Point is commonly used to manually control extinguishant release. EN 54-11 Certified Reports an alarm in under 0.2 seconds ‘Plug and Play’ terminal connections for faster wiring Continuity link for wiring test before commissioning Suitable for semi flush or surface mounting XP95 & Discovery compatible
Intelligent Manual Call Point – Yellow

SA5900-904APO The Manual Call Point is commonly used to manually control extinguishant release. Resettable operating element 170° viewable LED Suitable for semi flush or surface mounting ‘Plug and Play’ terminal connections for faster wiring Continuity link for wiring test before commissioning XP95, Discovery and CoreProtocol compatible
Intelligent Manual Call Point – White

SA5900-903APO The Manual Call Point is commonly used to manually initiate a hazard alert. Resettable operating element 170° viewable LED Suitable for semi flush or surface mounting ‘Plug and Play’ terminal connections for faster wiring Continuity link for wiring test before commissioning XP95, Discovery and CoreProtocol compatible
Intelligent Manual Call Point – Orange

SA5900-907APO The Manual Call Point is commonly used to manually control smoke vent systems. Resettable operating element 170° viewable LED Suitable for semi flush or surface mounting ‘Plug and Play’ terminal connections for faster wiring Continuity link for wiring test before commissioning XP95, Discovery and CoreProtocol compatible
Intelligent Manual Call Point – Green

SA5900-906APO The Manual Call Point is commonly used to manually release secure doors or barriers in the event of emergency. Resettable operating element 170° viewable LED Suitable for semi flush or surface mounting ‘Plug and Play’ terminal connections for faster wiring Continuity link for wiring test before commissioning XP95, Discovery and CoreProtocol compatible
Intelligent Manual Call Point – Blue

SA5900-905APO The Manual Call Point is commonly used to manually initiate a security alert. Resettable operating element 170° viewable LED Suitable for semi flush or surface mounting ‘Plug and Play’ terminal connections for faster wiring Continuity link for wiring test before commissioning XP95, Discovery and CoreProtocol compatible
Intelligent Manual Call Point

SA5900-908APO The Manual Call Point is used to manually initiate an alarm signal on the fire detection system. EN 54-11 & EN 54-17 Certified Resettable operating element 170° viewable LED Suitable for semi flush or surface mounting ‘Plug and Play’ terminal connections for faster wiring Continuity link for wiring test before commissioning XP95, Discovery and […]
Discovery Manual Call Point – Yellow

58100-927APO A seven-segment DIL switch enables addressing of each call point at commissioning stage. When operated, the manual call point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions. Plug and Play’ terminal connections for faster wiring Continuity link for wiring test before commissioning Suitable for semi flush or […]
Discovery Manual Call Point – Outdoor – Yellow – Isolating

58100-953APO The Manual Call Point is used to control extinguishant release rather than to initiate an alarm signal on the fire detection system. Suitable for weatherproof applications Reports an alarm in under 0.2 seconds ‘Plug and Play’ terminal connections for faster wiring Continuity link for wiring test before commissioning XP95 & Discovery compatible
Discovery Manual Call Point – Outdoor – Isolating

58200-951APO The Discovery Manual Call Point is used to manually initiate an alarm signal on the fire detection system. Suitable for weatherproof applications EN 54-11 & EN 54-17 Certified Resettable operating element 170° viewable LED XP95 & Discovery compatible
Discovery Manual Call Point – Outdoor

58200-950APO The Manual Call Point is used to manually initiate an alarm signal on the fire detection system. Suitable for weatherproof applications EN 54-11 Certified Resettable operating element 170° viewable LED XP95 & Discovery compatible