XP95 Sounder VID Base (Red Flash) – Isolating

45681-330APO XP95 Sounder Visual Indicator Base with integral isolated mounting base. Designed for indoor use. Two-Tone EN54-3 Sounder Selectable Volumes 55–75dB (A), 75–91dB (A) Visual Indicator Beacon (Red-Flash) XP95 (works on Discovery & CoreProtocol) 4″ Isolated Base EN54-17

XP95 Sounder VID Base (Red Flash)

45681-331APO The Sounder Visual Indicator Base is a loop-powered sounder and visual indicator combined with a standard Intelligent Mounting Base. It is used to signal a fire alarm in enclosed areas. Two volume ranges 55-75dB(A) and 75-91dB(A) Visual indicator flash rate of once per second Synchronisation of ‘alert’ and ‘evacuate’ tones Synchronisation of visual indicator […]

XP95 Sounder Base – Isolating

45681-277APO   XP95 Sounder Base with integral isolated mounting base. Designed for indoor use. Two Apollo Tones EN54-3 Sounder Selectable Volumes 55–75dB (A), 75–91dB (A) XP95 (works on Discovery & CoreProtocol) XPert7 Addressing 4″ Isolated Base

XP95 Sounder Base – Ancillary

45681-276APO   XP95 Sounder Base – Ancillary with mounting base. Designed for indoor use. Two Apollo Tones EN54-3 Sounder Multiple Selectable Volumes XP95 (works on Discovery & CoreProtocol) Activated via Detector head, does not take up an address 4″ Isolated Base EN54-17

XP95 Sounder Base

45681-278APO The sounder base comprises of a base sounder with integral mounting base and is for use with Discovery or XP95 ranges. It is designed for indoor use. Two tones Two volume ranges 55-75dB(A) and 75-91dB(A) Individual and group addressing Unique acoustic self-test

XP95 Open-Area VID – White Body (Red Flash) – Isolating

55000-010APO The XP95 Open-Area VID has been developed for use in situations where there is a risk that sounders will not be heard. For use with XP95 & Discovery systems Self-test fault monitoring IP65 rated Individual and group addressing Synchronisation of flashes Comes with Isolating Base as standard Loop-powered Red and clear lens option

XP95 Open-Area VID – White Body (Red Flash)

55000-878APO The XP95 Open-Area VID is a local-area visual indicator designed for indoor use. The visual indicator has been developed as a supplement to sounders for use in situations where there is a risk that sounders will not be heard. High intensity LEDs More reliable than xenon visual indicators Automatic LED check Lockable Wide angle […]

XP95 Open-Area VID – Red Body (Red Flash) – Isolating

55000-009APO The XP95 Open-Area VID has been developed for use in situations where there is a risk that sounders will not be heard. For use with XP95 & Discovery systems Self-test fault monitoring IP65 rated Individual and group addressing Synchronisation of flashes Comes with Isolating Base as standard Loop-powered Red and clear lens option

XP95 Open-Area VID – Red Body (Red Flash)

55000-877APO The XP95 Open-Area VID is a local-area visual indicator designed for indoor use. The visual indicator has been developed as a supplement to sounders for use in situations where there is a risk that sounders will not be heard. High intensity LEDs More reliable than xenon visual indicators Automatic LED check Lockable Wide angle […]

XP95 Open-Area VID – Amber Body (Amber Flash)

55000-879APO The XP95 Open-Area VID is a local-area visual indicator designed for indoor use. The visual indicator has been developed as a supplement to sounders for use in situations where there is a risk that sounders will not be heard. High intensity LEDs More reliable than xenon visual indicators Automatic LED check Lockable Wide angle […]

XP95 Open-Area Sounder VID – Red Body (Red Flash) – Isolating

55000-005APO XP95 Open-Area Sounder Visual Indicator with red body and red flash. Built-in isolator. EN54-3 Sounder Selectable Volumes 92dB (A), 100dB (A) Visual Indicator Beacon (Red Flash) XP95 (works on Discovery & CoreProtocol) 4″ Isolated Base EN54-17

XP95 Open-Area Sounder – White Body – Isolating

55000-002APO XP95 Open-Area Sounder with white body. Built-in isolator. EN54-3 Sounder Selectable Volumes 92dB (A), 100dB (A) XP95 (works on Discovery & CoreProtocol) 4″ Isolated Base EN54-17 VdS Approved

– XP95 Open-Area Multi-Tone Sounder VID – White Body (Red Flash) – Isolating

55000-294APO   The XP95 Open-Area Multi-Tone Sounder VID is designed for use in indoor open areas and can be connected to any Discovery or XP95 system. Choice of tones on standard device: Apollo, Slow Whoop and DIN Two volume settings 92dB(A) and 100dB(A) Synchronisation of ‘alert’ and ‘evacuate’ tones Individual and group addressing Built in […]

XP95 Open-Area Multi-Tone Sounder VID – Red Body (Red Flash) – Isolating

55000-293APO The XP95 Open-Area Multi-Tone Sounder VID is designed for use in indoor open areas and can be connected to any Discovery or XP95 system. Choice of tones on standard device: Apollo, Slow Whoop and DIN Two volume settings 92dB(A) and 100dB(A) Synchronisation of ‘alert’ and ‘evacuate’ tones Individual and group addressing Built in isolator […]