Conventional Open-Area Sounder VAD Cat. W – Red Body (White Flash) (W-3.1-11.3)

29600-804 Sonos Pulse conventional wall mounted Sounder Visual Alarm Devices are available with a white and red flash colour. The white flash variant has an EN 54-23 approved coverage pattern of W-3.1-11.3, whereas the red flash variant has a coverage pattern of W-2.4-7.5. The sounder has an a SPL of up to 97dB. EN 54-23 […]

Conventional Open-Area Sounder VAD Cat. W – Red Body (White Flash) (W-3.1-11.3)

29600-806 Sonos Pulse conventional wall mounted Sounder Visual Alarm Devices are available with a white and red flash colour. The white flash variant has an EN 54-23 approved coverage pattern of W-3.1-11.3, whereas the red flash variant has a coverage pattern of W-2.4-7.5. The sounder has an a SPL of up to 97dB. EN 54-23 […]

Conventional Open-Area Sounder VAD Cat. W – Red Body (Red Flash) (W-2.4-7.5)

29600-805 Sonos Pulse conventional wall mounted Sounder Visual Alarm Devices are available with a white and red flash colour. The white flash variant has an EN 54-23 approved coverage pattern of W-3.1-11.3, whereas the red flash variant has a coverage pattern of W-2.4-7.5. The sounder has an a SPL of up to 97dB. EN 54-23 […]

Conventional Open-Area Sounder VAD Cat. W – Red Body (Red Flash) (W-2.4-7.5)

29600-807 Sonos Pulse conventional wall mounted Sounder Visual Alarm Devices are available with a white and red flash colour. The white flash variant has an EN 54-23 approved coverage pattern of W-3.1-11.3, whereas the red flash variant has a coverage pattern of W-2.4-7.5. The sounder has an a SPL of up to 97dB. EN 54-23 […]

Conventional Open-Area Sounder VID – Red Body (Red Flash)

29600-323 The Conventional Open-Area Sounder VID is a conventional sounder visual indicator which makes use of the TimeSaver Base resulting in a faster and more reliable installation. For use with conventional systems A choice of 32 tones including all the major international standards Simple ‘First Fix’ installation Volume control – typical 8dB

Conventional Open-Area Sounder – Red Body

29600-322 The Conventional Open-Area Sounder is a conventional sounder which makes use of the TimeSaver Base resulting in a faster and more reliable installation. For use with conventional systems A choice of 32 tones including all the major international standards Simple ‘First Fix’ installation Volume control – typical 8dB

Conventional Open-Area AV TimeSaver Base – Shallow

29600-320 The Conventional Open-Area Sounder is a conventional sounder which makes use of the TimeSaver Base resulting in a faster and more reliable installation. For use with conventional systems A choice of 32 tones including all the major international standards Simple ‘First Fix’ installation Volume control – typical 8dB

Conventional Open-Area AV TimeSaver Base – Deep

29600-321 The Conventional Open-Area Sounder is a conventional sounder which makes use of the TimeSaver Base resulting in a faster and more reliable installation. For use with conventional systems A choice of 32 tones including all the major international standards Simple ‘First Fix’ installation Volume control – typical 8dB

Conventional Fire Bell 6″

29600-400 The Conventional Fire Bell 6″ is a motorised bell designed for fire alarm applications. Its low current consumption and universally recognisable alarm sound makes it an ideal choice for many alarm systems. Designed for ease of installation, it features a robust steel gong. Low current consumption Universally-recognisable sound

Series 65 to Orbis Base Adapter

ORB-BA-10008-APO The Series 65 to Orbis Base Adaptor is designed to allow Orbis detectors to be fitted to an existing Series 65 base. The adaptor eliminates the need to rewire an existing Apollo conventional system. Allows an existing range to be updated with ease Eliminates the need for re-wiring

Series 65 Base – Sav-Wire

45681-206APO The Series 65 Sav-Wire Base is designed to allow Series 65 detectors to be used in ‘Sav-Wire’ detection and alarm systems and can only be used in conjunction with a Sav-Wire compatible control panel. The base incorporates a circuit which detects the removal of a detector head. If a detector is removed from the […]

Series 65 Base – Relay (12V)

45681-508APO The base is designed for use in both fire and security systems. For fire systems a jumper on the PCB is fitted to a ‘latching’ position. For security systems the jumper is moved to another position so that the base is ‘non-latching’. Detector locking mechanism One-way fit Easy to wire Contains an earth connector […]

Series 65 Base – Relay

45681-245APO The base provides one set of volt-free, changeover (form C) contacts that change state when the detector signals an alarm. Detector locking mechanism One-way fit Easy to wire Contains an earth connector

Series 65 Base – End-of-Line Relay (24V)

45681-248APO The base is intended for use with four-wire circuits and features two sets of changeover contacts and a power supervision relay. Detector locking mechanism One way fit Easy to wire Contains an earth connector

Series 65 Base – End-of-Line Relay (12V)

45681-247APO The base is intended for use with four-wire circuits and features two sets of changeover contacts and a power supervision relay. Detector locking mechanism One way fit Easy to wire Contains an earth connector