Single Tube Duct Detector (RE-428 DU-S)

Easy to Install. One-pipe air sampling system. Patented Venture Pipe and Duct housing. Test hole on cover. Sampling tube Available 2ft. Available: Conventional / Addressable.

Special Detectors (RE-386 Series)

24V DC operation. Internal buzzer. 4 wire system operation. Detector auto reset once gas level fall below alarm relay output. N/O alarm relay output. Connects to Zone Module for addressable control and indicating equipment. Available :Natural Gas (Methane) / Carbon Monoxide (CO) / Propane Gas (LPG) Detectors.

Integrated Voice Evacuation System (Ekonics)

4 Audio inputs can configure output to 8 zones. Built-in 12 Programmable DVS / Alarm Messages. One push to talk Microphone provided for announcement. Interface via RS-485 / Triggering input. Zone wise input priority level. Zone wise selection through through Keypad. Voice recording option available.

Isolator Base RE-314 BI

Bidirectional protection device. Yellow color LED indication on active condition. Auto resettable while short rectified. Low standby current. Aluminium plated Screw terminals.

Mimic Card RE-517 MMC

Operates on 120-220 V AC. Provision for battery backup 24 v DC with Built in Charger. RS 485 Communication. Compatible with AVANI. 16 Zone outputs for mimic LED’s ( Expandable upto 64 Zones). DIP Switch addressing. Operates with respect to zone grouping of FACP.

Addressable MODBUS Converter RE-517TM

Give full details of detectors, outputs and inputs of Addressable FACP. 10/100M auto sensing Ethernet mini card for embedded device networking. TCP Server & UDPdriver operation modes.

Graphical Software Avani Soft

User friendly windows based software. Facility to monitor & control status of the FACP from the single windows. Visual and sound alerts for the fire and fault conditions. Instant pop up’s for nay event. For alarm management as well as system maintenance. All information available on a single screen allowing quick assessment 7 action. Facility […]

Repeater Panel RE-517 RP (ACTIVE)

160 Characters LCD display with touch keypad Remote silence and evacuate can be done for main panels in the network / system. RS 485 Communication for Network Repeater. 1000 Event storage with Real Time Clock.

Addressable GSM Module (RE-517 MG)

24V DC operation. Quad band GSM/ GPRS: 850/900/1800/1900 MHZ. Built in SIM (Subscriber identity module) card holder. Notification of exact fire location as in FAP. Maximum 10 numbers can be configured via RE-517 MG.

Addressable Ethernet Module (RE-517 ME)

10/100 auto sensing Ethernet mini card for embedded device networking. Ready- to- use TCP/IP firmware for fast integration. TCP server & UDP driver operation modes. Easy configuration with web browser, serial console, Telnet console or windows utility. Low power consumption.

Sounder RE-24CS

Slim and Sleek. Wall or Ceiling mountable. Sounder with Back Box. 24VDC Operation. Used in Fire, Burglar & Emergency Alarm System

Addressable Manual Call Point (RE-717M)

Type A Indoor use MCP. Module Status by RED LED Resettable by an element Kit. Suitable for flush or surface mounting. Module Addressing by 8 way DIP Switches. Low standby current.

Addressable Special Modules

Module status by RED LED Analogue communication with the panel. Module addressing by 8 way DIP switches. Blinking red LED for Normal condition. Steady red LED for Active condition. Low Standby Current. Available zone/ Isolator/ Input output Modules.

Sounder Cum Strobe (RE-716SS)

UL listed (UL 1971, ULC-S525, UL 464, ULC-526) 4 candela settings: 15/30/75/110cd output 2 audible tone settings: Continuously/ Temporal 3 High power cool white LED Max Current Draw (mA): 67-93mA) Flash Rate: 1 flash per second Operating voltage: 24VDC (16-33VDC) / FWR Sound level : 75 db to 85 db.