Beam Detector Prism Plate (1 prism)
Mounting Plate (1 Prism) for the Auto-Aligning Beam Detectors.
Beam Detector Extension Kit (50-100m)
Extension Kit for the Auto-Aligning Beam Detector.
Beam Detector Bracket
Universal Bracket for the Auto-Aligning Beam Detector.
Beam Detector Backbox
The Beam Detector Backbox allows easy first fixing of the cabling and terminations to the XP95 Reflective Beam Detector. The backbox can be surface or flush mounted.
XP95 DIN-Rail Zone Monitor Module – Isolating
The XP95 DIN-Rail Zone Monitor Module is used to power and control a zone of up to 20 Apollo Series 65, Orbis or equivalent fire detectors and report their status to the fire control panel. EN 54-17 & EN 54-18 Certified Allows conventional detection zones to be easily added to addressable systems Allows DIN-Rail mounting […]
XP95 DIN-Rail Mini Switch Monitor Module – Isolating
The XP95 DIN-Rail Mini Switch Monitor Module is used to monitor one or more single pole, volt free contacts connected on a single pair of cables and report status to fire control panel. EN 54-17 & EN 54-18 Certified Designed for use where space is limited Allows DIN-Rail mounting Priority and non-priority settings Pre-alarm’ status […]
XP95 DIN-Rail Isolator – Dual Channel
The XP95 DIN-Rail Isolator – Dual Channel provides two independent isolators which sense and isolate short circuits on Discovery and XP95 loops and spurs. Loop-powered Polarity sensitive Up to 20 detectors can be installed between isolators Allows fully isolated spurs
XP95 DIN-Rail Input/Output Module (250V AC)
The XP95 DIN-Rail Input/Output Module is used to monitor single pole, volt free contact inputs and control mains switching relay output contacts. EN 54-17 & EN 54-18 Certified Allows DIN-Rail mounting XP95, Discovery compatible
XP95 DIN-Rail AV Control Module (5 Amperes)
The XP95 DIN-Rail AV Control Module is used to control and monitor the operation of a circuit of conventional sounders or bells. EN 54-18 Certified Allows sounders to be operated 1 second on, 1 second off May be synchronised with loop sounders Allows DIN-Rail mounting XP95, Discovery compatible
Intelligent DIN-Rail Switch Monitor Module
The Intelligent DIN-Rail Switch Monitor Module is used to monitor one or more single pole, volt free contacts connected on a single pair of cables and report status to fire control panel. EN 54-17 & EN 54-18 Certified Priority and non-priority settings Switchable time delay on input for use when monitoring flow switches Ergonomic design […]
Intelligent DIN-Rail Input/Output Module
The Intelligent DIN-Rail Input/Output Module is used to monitor single pole, volt free contact inputs and control relay output contacts. EN 54-17 & EN 54-18 Certified Meets BS 7273-4 failsafe requirements Ergonomic design for ease of wiring and faster installation Allows DIN-Rail mounting XP95, Discovery and CoreProtocol compatible
XP95 Zone Monitor Module – Isolating
The XP95 Zone Monitor Module is used to power and control a zone of up to 20 Apollo Series 65, Orbis or equivalent fire detectors and report their status to the fire control panel. EN 54-17 & EN 54-18 Certified Allows conventional detection zones to be easily added to addressable systems Suitable for semi flush […]
XP95 Input/Output Module – Three Channel – Isolating
The XP95 Input/Output Module – Three Channel – Isolating is used to control and monitor the operation of a circuit of conventional sounders or bells. EN 54-17 & EN 54-18 Certified Allows independent monitoring of input channels Allows independent control of output relays XP95, Discovery compatible
XP95 AV Control Module – Isolating
The XP95 AV Control Module is used to control and monitor the operation of a circuit of conventional sounders or bells. EN 54-17 & EN 54-18 Certified Allows sounders to be operated 1 second on, 1 second off May be synchronised with loop sounders Suitable for semi flush or surface mounting XP95, Discovery compatible
Intelligent Switch Monitor Module (Twin)
The Intelligent Twin Switch Monitor Module provides the function of two Switch Monitor Modules to monitor one or more single pole, volt free contacts connected on a single pair of cables and report status to fire control panel. EN 54-17 & EN 54-18 Certified Priority and non-priority settings Switchable time delay on input for use […]